Violation Detail
Standard Cited: 19100147 C05 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1640500.015
Citation: 01006
Citation Type: Serious
Abatement Status:
Initial Penalty: $15,625.00
Current Penalty: $15,625.00
Issuance Date: 06/09/2023
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 06/29/2023
Gravity: 10
Report ID: 0524200
Contest Date: 07/05/2023
Final Order:
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | C: Contested | 07/06/2023 | $15,625.00 | 06/29/2023 | Serious | |
Penalty | Z: Issued | 06/09/2023 | $15,625.00 | 06/29/2023 | Serious |
Text For Citation: 01 Item/Group: 006 Hazard:
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing or blocking of machines or equipment from energy sources: a) Line B- On or about December 17, 2022, the employer failed to ensure that an adequate number of locks were provided to secure each energy source for use during lockout tagout on equipment, such as the Scanico Crust Spiral Freezer E11044 (Model SF135RR150/45-18,75-18, Serial 50937-2_2016).