Violation Detail
Standard Cited: 19100219 A02 Mechanical power-transmission apparatus.
Inspection Nr: 1635521.015
Citation: 01006
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $7,813.00
Current Penalty: $7,813.00
Issuance Date: 05/18/2023
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 06/07/2023
Gravity: 5
Report ID: 0317000
Contest Date: 06/12/2023
Final Order: 06/01/2024
Related Event Code (REC): C
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 06/01/2024 | $7,813.00 | 06/07/2023 | Serious | |
| Penalty | C: Contested | 06/13/2023 | $7,813.00 | 06/07/2023 | Serious | |
| Penalty | Z: Issued | 05/18/2023 | $7,813.00 | 06/07/2023 | Serious |
Text For Citation: 01 Item/Group: 006 Hazard:
29 CFR 1910.219(a)(2): Vertical and inclined belts were not guarded with a nip-point belt and pulley guard. a) Wheels America - 777 W Providence Road Lansdowne, PA: Wheel Blaster Area - On or about November 22, 2022, the employer did not ensure the vertical belt and pulley on the Wheel Blaster machine was guarded, thereby exposing employees to caught-in hazards.
Translate