Violation Detail
Standard Cited: 19100252 B02 III General requirements.
Inspection Nr: 1635082.015
Citation: 01006
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $4,687.00
Current Penalty: $2,812.00
Issuance Date: 05/03/2023
Nr Instances: 1
Nr Exposed: 20
Abatement Date:
Gravity: 1
Report ID: 0522300
Contest Date:
Final Order: 05/24/2023
Related Event Code (REC): C
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/24/2023 | $2,812.00 | Serious | ||
| Penalty | Z: Issued | 05/03/2023 | $4,687.00 | Serious |
Text For Citation: 01 Item/Group: 006 Hazard:
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields: On or about November 29, 2022, the employer did not supply welding curtains for the welders working in the Mig3 A-9 area who were located near aisleways.
Translate