Violation Detail
Standard Cited: 19100147 F03 II D The control of hazardous energy (lockout/tagout).
Inspection Nr: 1455742.015
Citation: 01006
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $4,866.00
Current Penalty: $3,016.92
Issuance Date: 02/04/2020
Nr Instances: 1
Nr Exposed: 6
Abatement Date:
Gravity: 1
Report ID: 0418100
Contest Date:
Final Order: 02/26/2020
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 02/26/2020 | $3,016.92 | Serious | ||
Penalty | Z: Issued | 02/04/2020 | $4,866.00 | Serious |
Text For Citation: 01 Item/Group: 006 Hazard:
29 CFR 1910.147(f)(3)(ii)(D): Each authorized employee did not affix a personal lockout or tagout device to the group lockout device before working on the machine or equipment: On or about 1/13/2020, in the production area at 2555 Moreland Avenue, Atlanta, GA: Employees performing servicing and maintenance activities such as but not limited to removing and replacing the blades on the band saw equipment were exposed to amputation and caught-in hazards, in that each authorized employee did not affix a lock and/or tag on the electrical energy source.