Violation Detail
Standard Cited: 19100147 C01 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1443325.015
Citation: 01006
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $9,446.00
Current Penalty: $4,723.00
Issuance Date: 03/23/2020
Nr Instances: 1
Nr Exposed: 5
Abatement Date: 04/06/2020
Gravity: 10
Report ID: 0418800
Contest Date:
Final Order: 04/15/2020
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/15/2020 | $4,723.00 | 04/06/2020 | Serious | |
Penalty | Z: Issued | 03/23/2020 | $9,446.00 | 04/06/2020 | Serious |
Text For Citation: 01 Item/Group: 006 Hazard:
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: On or about 11/7/2019, at Assura Windows and Doors LLC, 1543 N Powerline Rd, Pompano Beach, FL 33069. An energy control program was not developed and/or implemented for protecting authorized and affected employees from caught by hazards whenever equipment was serviced and/or maintained.