Violation Detail
Standard Cited: 19100212 A01 General requirements for all machines.
Inspection Nr: 1417453.015
Citation: 01006
Citation Type: Serious
Abatement Date: 02/12/2020 2
Initial Penalty: $6,747.00
Current Penalty: $4,383.00
Issuance Date: 01/21/2020
Nr Instances: 2
Nr Exposed: 3
Related Event Code (REC):
Gravity: 5
Report ID: 0213900
Contest Date:
Final Order: 02/12/2020
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 02/12/2020 | $4,383.00 | 02/12/2020 | Serious | |
Penalty | Z: Issued | 01/21/2020 | $6,747.00 | 02/12/2020 | Serious |
Text For Citation: 01 Item/Group: 006 Hazard:
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. a) Lab 1: The Carbon Dioxide pumps Model# P 200 Serial# 4009957 and Serial# 4077722 were not guarded to protect employees that are in close proximity of a rotating part. On or about 7/24/19. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.