Violation Detail
Standard Cited: 19100213 H01 Woodworking machinery requirements.
Inspection Nr: 1405553.015
Citation: 01006
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $9,377.00
Current Penalty: $9,377.00
Issuance Date: 07/18/2019
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 08/09/2019
Gravity: 5
Report ID: 0419400
Contest Date:
Final Order: 08/16/2019
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 07/18/2019 | $9,377.00 | 08/09/2019 | Serious |
Text For Citation: 01 Item/Group: 006 Hazard:
29 CFR 1910.213(h)(1): The upper hood shall completely enclose the upper portion of the blade down to a point that will include the end of the saw arbor. The upper hood shall be constructed in such a manner and of such material that it will protect the operator from flying splinters, broken saw teeth, etc., and will deflect sawdust away from the operator. The sides of the lower exposed portion of the blade shall be guarded to the full diameter of the blade by a device that will automatically adjust itself to the thickness of the stock and remain in contact with stock being cut to give maximum protection possible for the operation being performed. (a) Delta Radial Arm Saw - On or about May 31, 2019 the employer did not ensure that the lower portion of the blade was guarded, exposing employees to an amputation hazard.