Violation Detail
Standard Cited: 19100147 C06 II The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1383066.015
Citation: 01006
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $11,934.00
Current Penalty: $0.00
Issuance Date: 08/30/2019
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 09/24/2019
Gravity: 10
Report ID: 0627510
Contest Date:
Final Order: 08/17/2022
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/17/2022 | $0.00 | 09/24/2019 | Serious | |
Penalty | Z: Issued | 08/30/2019 | $11,934.00 | 09/24/2019 | Serious |
Text For Citation: 01 Item/Group: 006 Hazard:
29 CFR 1910.147(c)(6)(ii): The employer shall certify that the periodic inspections have been performed. The certification shall identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection: On or about March 4, 2019, and at times prior thereto, at the tank battery train #7, employees performed maintenance and/or repairs to a level controller/float on the heater treater oil boot and peanut valve. The employer did not ensure periodic inspections were performed on the energy control procedures to ensure they were being followed.