Violation Detail
Standard Cited: 19100219 C02 I Mechanical power-transmission apparatus.
Inspection Nr: 1377408.015
Citation: 01006
Citation Type: Serious
Abatement Date: 08/22/2019 2
Initial Penalty: $7,577.00
Current Penalty: $2,000.00
Issuance Date: 08/06/2019
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 5
Report ID: 0213600
Contest Date: 08/28/2019
Final Order: 05/07/2020
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 05/07/2020 | $2,000.00 | 08/22/2019 | Serious | |
Penalty | C: Contested | 09/04/2019 | $7,577.00 | 08/22/2019 | Serious | |
Penalty | Z: Issued | 08/06/2019 | $7,577.00 | 08/22/2019 | Serious |
Text For Citation: 01 Item/Group: 006 Hazard:
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: a) On or about 02/11/19 on the Line #3 packing conveyor; employees were exposed to caught in hazard of the unguarded shafting on the drive end of the conveyor when removing packages from this conveyor. ABATEMENT CERTIFICATION REQUIRED