Violation Detail
Standard Cited: 19100254 D09 III Arc welding and cutting.
Inspection Nr: 1362345.015
Citation: 01006
Citation Type: Serious
Abatement Status: Not Completed - AD Discretion
Initial Penalty: $6,630.00
Current Penalty: $6,200.00
Issuance Date: 05/02/2019
Nr Instances: 1
Nr Exposed: 10
Abatement Date: 06/14/2019
Gravity: 5
Report ID: 0316400
Contest Date:
Final Order: 05/24/2019
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/24/2019 | $6,200.00 | 06/14/2019 | Serious | |
Penalty | Z: Issued | 05/02/2019 | $6,630.00 | 05/14/2019 | Serious |
Text For Citation: 01 Item/Group: 006 Hazard:
29 CFR 1910.254(d)(9)(iii): Cables with damaged insulation or exposed bare conductors were not replaced: (a) Welding department - On or about 11/16/18, the employer did not replace welding cables with damaged insulation, exposing employees to electrical shocks and burns.