Violation Detail
Standard Cited: 19100334 A02 II Use of equipment.
Inspection Nr: 1354903.015
Citation: 01006
Citation Type: Serious
Abatement Status: Quick Fix
Initial Penalty: $3,738.00
Current Penalty: $1,869.00
Issuance Date: 12/18/2018
Nr Instances: 2
Nr Exposed: 11
Abatement Date:
Gravity: 5
Report ID: 0112000
Contest Date:
Final Order: 01/23/2019
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 01/23/2019 | $1,869.00 | Serious | ||
Penalty | Z: Issued | 12/18/2018 | $3,738.00 | Serious |
Text For Citation: 01 Item/Group: 006 Hazard:
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service: A. Dry Dock 1: On, or about, October 19, 2018, a yellow extension cord used to energize a blower was damaged and wrapped with electrical tape. B. Near Red Barge: On, or about, October 19, 2018, a yellow extension cord used to provide shore power to the vessel Adam was damaged and wrapped with electrical tape. Also, the cord had been flattened from vehicles driving over the cord.