Violation Detail
Standard Cited: 19100212 A01 General requirements for all machines.
Inspection Nr: 1308095.015
Citation: 01006
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $6,467.00
Current Penalty: $4,773.00
Issuance Date: 09/21/2018
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 10/03/2018
Gravity: 5
Report ID: 0316700
Contest Date: 10/12/2018
Final Order: 01/09/2019
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 01/09/2019 | $4,773.00 | 10/03/2018 | Serious | |
| Penalty | C: Contested | 10/15/2018 | $6,467.00 | 10/03/2018 | Serious | |
| Penalty | Z: Issued | 09/21/2018 | $6,467.00 | 10/03/2018 | Serious |
Text For Citation: 01 Item/Group: 006 Hazard:
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Machine Shop- The employer did not provide machine guarding on the unused portion of the blade of the Cosen SH-500M horizontal pivot band saw on or about April 11, 2018. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.