Violation Detail
Standard Cited: 19100147 C07 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1275669.015
Citation: 01006
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $7,760.00
Current Penalty: $3,880.00
Issuance Date: 02/13/2018
Nr Instances: 1
Nr Exposed: 4
Abatement Date:
Gravity: 5
Report ID: 0522300
Contest Date:
Final Order: 03/12/2018
Related Event Code (REC): C
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 03/12/2018 | $3,880.00 | Serious | ||
| Penalty | Z: Issued | 02/13/2018 | $7,760.00 | Serious |
Text For Citation: 01 Item/Group: 006 Hazard:
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: On or about November 7, 2017, the employer did not provide lockout/tagout training to the employees. The employees use the following machines, that require lock out/tag out, to include but not limited to: the Solid Surface Mixer, Large Mixer, Medium Mixer, small mixer south, small mixer north, Hostess carts #1 -#4, bucket vein mixer, Powermatic RB37 wide belt sander, Sallair 1800 Compressor, Hitachi CLOFSB radial arm saw, Hitachi CLOFSB radial arm saw, Ryobi radial arm saw, and Excaliber radial arm saw.
Translate