Violation Detail
Standard Cited: 19261052 B01 Stairways.
Inspection Nr: 1219667.015
Citation: 01006
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $2,173.00
Current Penalty: $2,173.00
Issuance Date: 09/19/2017
Nr Instances: 1
Nr Exposed: 5
Abatement Date:
Gravity: 5
Report ID: 0215000
Contest Date:
Final Order: 10/17/2017
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 09/19/2017 | $2,173.00 | Serious |
Text For Citation: 01 Item/Group: 006 Hazard:
29 CFR 1926.1052(b)(1): Foot traffic was not prohibited on stairways where the treads and/or landings of pan stairs were to be filled in with concrete or other material at a later date and stairs were not temporarily fitted with wood or other solid material at least to the top edge of each pan. Site: 313 52nd Street, Brooklyn, NY On or about 3/23/2017 a) The treads and landings of the pan stairs were not filled or fitted with any solid material to the top edge of each pan. Employees used these stairs to travel between floors.
Translate