Violation Detail
Standard Cited: 19100219 C04 I Mechanical power-transmission apparatus.
Inspection Nr: 1170742.015
Citation: 01006
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $6,236.00
Current Penalty: $2,494.40
Issuance Date: 10/13/2016
Nr Instances: 2
Nr Exposed: 2
Abatement Date: 10/28/2016
Gravity: 5
Report ID: 0626600
Contest Date:
Final Order: 10/19/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/19/2016 | $2,494.40 | 10/28/2016 | Serious | |
Penalty | Z: Issued | 10/13/2016 | $6,236.00 | 11/01/2016 | Serious |
Text For Citation: 01 Item/Group: 006 Hazard:
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft: On or about August 16, 2016: a. On west side of the wood planer where employees were exposed to struck-by and caught-by hazards while working near a shaft end that was part of the drive assembly for the Pineapple and speed up rollers without a guard to cover the shaft end that did not present a smooth edge and projected more than one half the diameter of the shaft. b. On west side of the wood planer where employees were exposed to struck-by and caught-by hazards while working near a shaft end that was part of the drive assembly for the wood planer without a guard to cover the shaft end that did not present a smooth edge and projected more than one half the diameter of the shaft.