Violation Detail
Standard Cited: 19100212 A05 General requirements for all machines.
Inspection Nr: 1151948.015
Citation: 01006
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $4,900.00
Current Penalty: $3,430.00
Issuance Date: 07/27/2016
Nr Instances: 1
Nr Exposed: 7
Abatement Date: 08/22/2016
Gravity: 10
Report ID: 0418100
Contest Date:
Final Order: 08/10/2016
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/10/2016 | $3,430.00 | 08/22/2016 | Serious | |
Penalty | Z: Issued | 07/27/2016 | $4,900.00 | 08/22/2016 | Serious |
Text For Citation: 01 Item/Group: 006 Hazard:
29 CFR 1910.212(a)(5): Fan blade guard(s) were not provided where the periphery of the blades was less than seven feet from the floor or working level: On or about 6/2/2016 in the equipment/chemical area of the facility located at 2434 West Broad Street in Athens, GA: The ventilation fan blades in the employee(s) work area were not guarded to protect the employee(s) being exposed to an amputation hazard. On 5/28/16 two of an employees fingers were amputated by the unguarded rotating ventilation fan blades.