Violation Detail
Standard Cited: 19100023 B04 Ladders.
Inspection Nr: 1099140.015
Citation: 01006
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $5,000.00
Current Penalty: $1,500.00
Issuance Date: 04/08/2016
Nr Instances: 1
Nr Exposed: 11
Abatement Date: 04/22/2016
Gravity:
Report ID: 0625700
Contest Date: 04/29/2016
Final Order: 11/03/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 11/03/2016 | $1,500.00 | 04/22/2016 | Other | |
Penalty | C: Contested | 05/03/2016 | $5,000.00 | 04/22/2016 | Serious | |
Penalty | Z: Issued | 04/08/2016 | $5,000.00 | 04/22/2016 | Serious |
Text For Citation: 01 Item/Group: 006 Hazard:
29 CFR 1910.23(b)(4): Every temporary wall opening did not have adequate guards: On or about 10/16/2015, on the second level platform in the nitrogen freezer room, the employer allowed employees to work on the second level platform while placing the nitrogen freezer out-of-service and did not ensure that the freezer hatch was guarded when opened.