Violation Detail
Standard Cited: 19100212 A05 General requirements for all machines.
Inspection Nr: 1069465.015
Citation: 01006
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $5,500.00
Current Penalty: $5,500.00
Issuance Date: 12/04/2015
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 12/14/2015
Gravity: 5
Report ID: 0112600
Contest Date:
Final Order: 12/18/2015
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 12/18/2015 | $5,500.00 | 12/14/2015 | Serious | |
Penalty | Z: Issued | 12/04/2015 | $5,500.00 | 12/14/2015 | Serious |
Text For Citation: 01 Item/Group: 006 Hazard:
29 CFR 1910.212(a)(5): Fan blade guard(s) were not provided where the periphery of the blades was less than seven feet from the floor or working level: Die Shop, Oil heater for machine 6045, Wyman Gordon, 244 Worcester Street, North Grafton, Massachusetts; The employer did not ensure fan blades were provided with guards where the periphery of the blades was less than seven feet from the working level and approximately 4 inches from the open side of the machine. The side cover of the oil heater had been removed, exposing employees to unguarded fan blades.