Violation Detail
Standard Cited: 19100217 B08 I Mechanical power presses.
Inspection Nr: 1051410.015
Citation: 01006
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $5,500.00
Current Penalty: $5,000.00
Issuance Date: 09/24/2015
Nr Instances: 2
Nr Exposed: 3
Related Event Code (REC):
Gravity: 5
Report ID: 0418400
Contest Date: 10/15/2015
Final Order: 08/08/2016
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 08/08/2016 | $5,000.00 | Serious | ||
Penalty | C: Contested | 10/27/2015 | $5,500.00 | Serious | ||
Penalty | Z: Issued | 09/24/2015 | $5,500.00 | Serious |
Text For Citation: 01 Item/Group: 006 Hazard:
29 CFR 1910.217(b)(8)(i): Power press control system(s) on mechanical power press(es) were not provided with main power disconnect switch(es), capable of being locked only in the off position: a) Pail Department - On or about March 31, 2015 and at times prior to, the power press control system on the Bliss PP017 full revolution mechanical power press was equipped with a disconnect switch that was not capable of being locked only in the off position, thus exposing employees to an amputation hazard. b) Ammo Department - On or about April 1, 2015 and at times prior to, the power press control system on the AMO503P full revolution mechanical power press was equipped with a disconnect switch that was not capable of being locked only in the off position, thus exposing employees to an amputation hazard.