Violation Detail
Standard Cited: 19100253 B05 II D Oxygen-fuel gas welding and cutting.
Inspection Nr: 849104.015
Citation: 01005E
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $4,950.00
Current Penalty: $0.00
Issuance Date: 07/26/2013
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 08/25/2013
Gravity: 5
Report ID: 0626700
Contest Date: 08/15/2013
Final Order: 06/05/2014
Related Event Code (REC): A
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 06/05/2014 | $0.00 | 08/25/2013 | Serious | |
Penalty | C: Contested | 08/19/2013 | $4,950.00 | 08/25/2013 | Serious | |
Penalty | Z: Issued | 07/26/2013 | $4,950.00 | 08/25/2013 | Serious |
Text For Citation: 01 Item/Group: 005E Hazard:
29 CFR 1910.253(b)(5)(ii)(D): Cylinders were not secured on a special truck, regulators were not removed and valve protection caps, when provided for, were not put in place before cylinders were moved: At the facility, in the mechanic shop and yard areas: On January 26, 2013, cylinders on an oxy-acetylene special truck with regulators attached were not secured in place before being moved from the mechanical shop to the yard where a laborer used the cutting torch to cut used chemical drums, exposing employees to a projectile struck by hazard.