Violation Detail
Standard Cited: 19100305 B01 II Wiring methods, components, and equipment for general use.
Inspection Nr: 1771676.015
Citation: 01005D
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $4,610.00
Current Penalty: $0.00
Issuance Date: 12/05/2024
Nr Instances: 2
Nr Exposed: 11
Abatement Date:
Gravity: 5
Report ID: 0626600
Contest Date: 02/10/2025
Final Order: 03/26/2025
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 03/26/2025 | $0.00 | Serious | ||
Penalty | C: Contested | 03/10/2025 | $4,610.00 | Serious | ||
Penalty | Z: Issued | 12/05/2024 | $4,610.00 | Serious |
Text For Citation: 01 Item/Group: 005D Hazard:
29 CFR 1910.305(b)(1)(ii):Unused openings in boxes, cabinets, or fittings were not effectively closed: 1. On or about August 26, 2024, at the hole tech work area an employee was utilizing an electrical breaker box that had exposed breakers/switches. 2. On or about August 27, 2024, at the loading dock work area employees were utilizing an air compressor switch which did not have its guard in place.