Violation Detail
Standard Cited: 19261101 G08 II F Asbestos
This violation item has been deleted.
Inspection Nr: 1328349.015
Citation: 01005D
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 11/01/2018
Nr Instances: 1
Nr Exposed: 6
Abatement Date:
Gravity: 5
Report ID: 0522000
Contest Date:
Final Order: 11/27/2018
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 11/27/2018 | $0.00 | Serious | ||
Penalty | Z: Issued | 11/01/2018 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 005D Hazard:
29 CFR 1926.1101(g)(8)(ii)(F): Upon being lowered, unwrapped material shall be transferred to a closed receptacle in such manner so as to preclude the dispersion of dust. The controlling employer did not ensure that unwrapped asbestos-containing shingles were lowered and transferred to a closed receptacle in that on June 14, 2018, subcontractor employees broke up roof shingles and threw shingles off the roof at heights greater than 23 feet. Bulk samples revealed that the shingles contained 10.38% chrysotile asbestos and the mastic contained 14.25% chrysotile asbestos..