Violation Detail
Standard Cited: 19100134 F01 Respiratory Protection.
Inspection Nr: 1313291.015
Citation: 01005D
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 06/19/2018
Nr Instances: 1
Nr Exposed: 10
Abatement Date: 07/23/2018
Gravity: 5
Report ID: 0522000
Contest Date:
Final Order: 06/27/2018
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 06/27/2018 | $0.00 | 07/23/2018 | Serious | |
Penalty | Z: Issued | 06/19/2018 | $0.00 | 07/23/2018 | Serious |
Text For Citation: 01 Item/Group: 005D Hazard:
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): The employer required tight-fitting facepiece respirator use for employees who conduct grinding of material, spray painting, welding, and application of resins, but did not ensure that employees received fit-testing.