Violation Detail
Standard Cited: 19100217 C02 III Mechanical power presses.
Inspection Nr: 1633774.015
Citation: 01005C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 12/12/2022
Nr Instances: 6
Nr Exposed: 4
Abatement Date: 07/28/2023
Gravity: 5
Report ID: 0112000
Contest Date:
Final Order: 01/18/2023
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | P: Petition to Mod Abatement | 03/17/2023 | $0.00 | 07/28/2023 | Serious | |
Penalty | I: Informal Settlement | 01/18/2023 | $0.00 | 04/28/2023 | Serious | |
Penalty | Z: Issued | 12/12/2022 | $0.00 | 01/31/2023 | Serious |
Text For Citation: 01 Item/Group: 005C Hazard:
29 CFR 1910.217(c)(2)(iii): Fixed barrier guard(s) on mechanical power press(es) were not attached securely to the frame of the press or to the bolster plate: Press Room: On, or about, November 4, 2022, the following partial revolution mechanical power presses were provided with expanded metal barrier guards that hung in front of the press on hooks and were not affixed to the press: A. Press #33, Bliss. B. Press #22, Perkins. C. Press #17, Niagara. D. Press #46, Bliss. E. Press #24, Bliss. F. Press #23, Minster.