Violation Detail
Standard Cited: 19100219 F01 Mechanical power-transmission apparatus.
Inspection Nr: 1622298.015
Citation: 01005C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $12,278.00
Current Penalty: $0.00
Issuance Date: 03/01/2023
Nr Instances: 2
Nr Exposed: 20
Abatement Date: 07/03/2023
Gravity: 5
Report ID: 0521100
Contest Date:
Final Order: 03/23/2023
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/23/2023 | $0.00 | 07/03/2023 | Serious | |
Penalty | Z: Issued | 03/01/2023 | $12,278.00 | 03/29/2023 | Serious |
Text For Citation: 01 Item/Group: 005C Hazard:
29 CFR 1910.219(f)(1): Gears shall be guarded in accordance with one of the methods identified in sections 1910.219(f)(1)(i)-1910.219(f)(1)(iii) of this part. With respect to an establishment located at 1400 Plover Road, Plover, WI 54467, employees were exposed to potential pinch point hazards: a) on or about September 27, 2022 when the guard for the rotating drive gears of the filler drums in the green bean canning area did not adequately protect employees from the in-running nip points. b) on or about October 20, 2022 when the guard for the rotating drive gears of the filler drums in the root crop canning area did not adequately protect employees from the in-running nip points.