Violation Detail
Standard Cited: 19100219 C04 I Mechanical power-transmission apparatus.
Inspection Nr: 1210687.015
Citation: 01005C
Citation Type: Serious
Abatement Date: 01/31/2018 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 05/02/2017
Nr Instances: 2
Nr Exposed: 11
Related Event Code (REC):
Gravity: 5
Report ID: 0522500
Contest Date: 05/26/2017
Final Order: 02/15/2018
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 02/15/2018 | $0.00 | 01/31/2018 | Serious | |
Penalty | C: Contested | 06/02/2017 | $0.00 | 05/12/2017 | Serious | |
Penalty | Z: Issued | 05/02/2017 | $0.00 | 05/12/2017 | Serious |
Text For Citation: 01 Item/Group: 005C Hazard:
29 CFR 1910.219(c)(4)(i): Projecting shaft ends shall present a smooth edge and end and shall not project more than one-half the diameter of the shaft unless guarded by nonrotating caps or safety sleeves. a. Located at the Slitter 1 line: On or about March 1, 2017 and at times prior, employees were exposed to a caught in hazard while operating, observing, and inspecting material being processed on the line as a result of two unguarded, approximately two and a half inches in diameter, arbor shaft ends projecting out the side of the slitter frame approximately two and a half inches. b. Located at the Slitter 1 line: On or about February 14, 2017 and at times prior, employees were exposed to a caught in hazard while operating, observing, and inspecting material being processed on the line as a result an unguarded, approximately three and a half inch shaft projecting out the side of the chopper machine approximately thirty four inches.