Violation Detail
Standard Cited: 19100219 M01 I Mechanical power-transmission apparatus.
Inspection Nr: 1178747.015
Citation: 01005C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 12/01/2016
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 12/20/2016
Gravity: 5
Report ID: 0626600
Contest Date:
Final Order: 12/22/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 12/22/2016 | $0.00 | 12/20/2016 | Serious | |
Penalty | Z: Issued | 12/01/2016 | $0.00 | 12/20/2016 | Serious |
Text For Citation: 01 Item/Group: 005C Hazard:
29 CFR 1910.219(m)(1)(i): Standard conditions were not secured by the use of the following materials: expanded metal, perforated or solid sheet metal, wire mesh on a frame of angle iron, or iron pipe securely fastened to floor or to frame of machine: On or about September 20, 2016, and times prior thereto, in the Mill Area where employees were exposed to struck-by and caught-in hazards when operating a Yates-American A20 Planer without an expanded metal guard being securely fastened to floor or to frame of machine.