Violation Detail
Standard Cited: 19100146 C04 Permit-required confined spaces
Inspection Nr: 1091131.015
Citation: 01005C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 02/22/2016
Nr Instances: 2
Nr Exposed: 4
Abatement Date: 04/15/2016
Gravity: 10
Report ID: 0626300
Contest Date:
Final Order: 03/15/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/15/2016 | $0.00 | 04/15/2016 | Serious | |
Penalty | Z: Issued | 02/22/2016 | $0.00 | 03/17/2016 | Serious |
Text For Citation: 01 Item/Group: 005C Hazard:
29 CFR 1910.146(c)(4): When the employer decided that its employees would enter permit spaces, the employer did not develop and implement a written permit space entry program that complied with 29 CFR 1910.146: a) Sawmill building 2, employees were required to enter a permit required confined space to clean the dust chain pit without using the safety procedures that would be outlined in a permit required confined space entry program. b) Sawmill building 4, employees were required to enter a permit required confined space to clean the dust chain pit without using the safety procedures that would be outlined in a permit required confined space entry program.