Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 993351.015
Citation: 01005B
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 03/03/2015
Nr Instances: 1
Nr Exposed: 124
Abatement Date: 04/05/2015
Gravity:
Report ID: 0215800
Contest Date: 03/20/2015
Final Order: 03/31/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 03/31/2016 | $0.00 | 04/05/2015 | Other | |
Penalty | C: Contested | 03/25/2015 | $0.00 | 04/05/2015 | Serious | |
Penalty | Z: Issued | 03/03/2015 | $0.00 | 04/05/2015 | Serious |
Text For Citation: 01 Item/Group: 005B Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) World Kitchen, LLC, on or about 10/9/14: The employer did not conduct a periodic inspection of their energy control procedures at least annually. Employees perform servicing and/or maintenance activities on machinery and equipment such as but not limited to: Production Hubs, Fire Polishers, Banders, Cooling Fans, Compressors and Kilns.