Violation Detail
Standard Cited: 19261127 G02 I Cadmium
Inspection Nr: 907402.015
Citation: 01005B
Citation Type: Serious
Abatement Date: 11/11/2013 5
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 11/01/2013
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): C
Gravity: 10
Report ID: 0625700
Contest Date:
Final Order: 12/30/2013
Emphasis:
Substance: C141
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 11/01/2013 | $0.00 | 11/11/2013 | Serious |
Text For Citation: 01 Item/Group: 005B Hazard:
29 CFR 1926.1127(g)(2)(i): The employer did not implement a respiratory protection program in accordance with 29 CFR 1910.134(b) through (d), (except (d)(1)(iii)), and (f) through (m)), which covers each employee required by 29 CFR 1926.1127 to use a respirator. On or about May 14, 2013, at the residential home remodeling project located at 2621 Prytania St., New Orleans, LA, the employer did not protect at least one employee from exposure to cadmium in excess of 5 micrograms per cubic meter (Permissible Exposure Limit) as an 8 hour Time Weighted Average while removing paint from the exterior siding using a power sander. The work was performed in an unsealed containment on the east side of the house. The employee was documented to be exposed to airborne cadmium levels of 14 ug/m(3), which is equivalent to 2.86 times the PEL. This exposure was determined from one 309 minute sample. Zero exposure was assumed for the unsampled 171 minute period. Employees were exposed to the hazards of systemic poisoning.