Violation Detail
Standard Cited: 19261437 N05 V
Inspection Nr: 504978.015
Citation: 01005B
Citation Type: Serious
Abatement Date: 02/14/2013 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 12/27/2012
Nr Instances: 2
Nr Exposed: 9
Related Event Code (REC): A
Gravity: 10
Report ID: 0521100
Contest Date: 01/18/2013
Final Order: 02/07/2014
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 02/07/2014 | $0.00 | 02/14/2013 | Serious | |
Penalty | C: Contested | 04/08/2013 | $0.00 | 02/14/2013 | Serious | |
Penalty | Z: Issued | 12/27/2012 | $0.00 | 02/14/2013 | Serious |
Text For Citation: 01 Item/Group: 005B Hazard:
29 CFR 1926.1437(n)(5)(v): The systems/means of securement of the crane to the barge used to comply with options 1-4 of this section were not designed by a qualified person familiar with floating crane/derrick design. On and about July 5, 2012 the Terex HC 110 crawler crane on the south barge and the American 9299 crawler crane on the north barge were not secured to the barges by any of the means listed in options 1-4 and were not designed by a qualified person as described in this section. Thereby, employees were exposed to hazards from crane and load failure.