Violation Detail
Standard Cited: 6A0001 General Duty Clause
Inspection Nr: 311211296
Citation: 01005B
Citation Type: Serious
Abatement Status: E
Initial Penalty:
Current Penalty:
Issuance Date: 05/03/2010
Nr Instances: 1
Nr Exposed: 30
Abatement Date: 06/04/2010
Gravity: 10
Report ID: 0257260
Contest Date: 05/21/2010
Final Order:
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | J: ALJ Decision | 04/26/2012 | 06/04/2010 | Serious | ||
| Penalty | Z: Issued | 05/03/2010 | 06/04/2010 | Serious |
Text For Citation: 01 Item/Group: 005B Hazard: EXPLOSION
Section 6(a) of the Puerto Rico Occupational Safety and Health Act: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or physical harm to employees in that employees were exposed to: Seccion 6(a) de la Ley de Seguridad y Salud en el Trabajo de Puerto Rico: El patrono no proveyo empleo y un sitio de empleo libre de riesgos reconocidos que esten causando o que puedan causar muerte o dano fisico a los empleados, por cuanto empleados estaban expuestos a: API - 2610 - MAY 2005 This standard covers Design, Construction, Operation, Maintenance, and Inspection of Terminal & Tank Facilities associated with marketing, refining, pipeline, and other similar activities. The purpose of this standard is to consolidate a wide base of current industry experience, knowledge, information, and management practices into a cohesive standard compromising a range of best practices. a)Employees that worked at CAPECO performing routine task such as tank operator,waste treatment operator, loading rack operator, among others were exposed or could be exposed to flammable and combustible release, fire and or explosion. The employer has no Management of Change (MOC) for the installation and operation of tanks 409 and 107, which would have included the safety and health impacts of not installing an automatic tank overfilling system, the lack of formal written operating procedures for tank filling operations, or the development and implementation of maintenance procedures for tank level systems including the calibration of the tank level readings at the operators console, with the tank gauge levels and the actual levels contained in the tanks. b)No MOC from the change from those tanks systems that were originally installed with automatic overfill systems but due to maintenance issues with those system, CAPECO decided to use only unwritten operating procedures to control tank filling operations. Among other methods, one feasible and acceptable abatement method to correct this hazard is: 1.Follow API 2610 - 6.6 Management of Change. Systems shall be established for each facility to review potential health, safety, and environmental considerations resulting from proposed additions, modifications, or other changes that may periodically occur in the facility. The following changes should be properly managed by identifying and reviewing them before implementation: a.Materials or products handled.b.Equipment used or installed. c.Operations and procedures. API 2610 MAYO 2005 Este reglamento abarca el Diseno, Construccion, Operacion, Mantenimiento e Inspecciones de Facilidades de Terminal y Tanques asociadas con mercadeo, refinacion, sistema de tuberia y otras actividades similares. El proposito de este reglamento es consolidar con una base considerable de experiencia en la industria actualizado, conocimiento, informacion y practicas gerenciales en un reglamento consistente, comprometiendo una gama de las mejores practicas. a)Empleados que trabajaban en CAPECO, realizando tareas rutinarias tales como operador de tanque, operador de tratamiento de aguas, operador de area de carga, entre otros fueron o podrian haber estado expuestos a liberacion de productos quimicos inflamables, combustible, fuego y/o explosion. El patrono no tenia el Manejo de Cambio (MOC) para la instalacion y operacion de los tanques 409 y 107, que habria incluido las consecuencias a la seguridad y a la salud por no instalar un sistema de sobre llenado automatico, la falta de procedimientos operacionales escritos formales para las operaciones de llenado de tanques, o el desarrollo e implementacion de procedimientos de mantenimiento para los sistemas de nivel de tanques incluyendo la calibracion de las lecturas del nivel de los tanques en las consola de los operadores con los indicadores de nivel de los tanques y los niveles reales que contenian los tanques. b)No se realizo MOC para aquellos tanques que debido a asuntos de mantenimiento se cambiaron de un sistema de sobrellenado automatico a uno no automatico, donde utilizaron solo procedimientos de operacion no escritos para controlar las operaciones de llenado. Entre varios metodos, uno metodo de correccion aceptable y factible para corregir este riesgo es: 1.Seguir el API 2610 - 6.6 El Manejo de Cambio. Los sistemas deben ser establecidos para cada facilidad para revisar las consideraciones potenciales al ambiente, a la seguridad y a la salud que resulte de los suplementos, modificaciones, u otros cambios propuestos que pueden ocurrir periodicamente en la facilidad. Los siguientes cambios deben ser manejados de forma correcta mediante la identificacion y revision antes de implementarlos: a.Materiales o productos manejados. b.Equipo utilizado o instalado. c.Procesos y procedimientos.
Translate