Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1734041.015
Citation: 01005B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 05/30/2024
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 06/26/2024
Gravity: 5
Report ID: 0316700
Contest Date:
Final Order: 06/18/2024
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 06/18/2024 | $0.00 | 06/26/2024 | Serious | |
Penalty | Z: Issued | 05/30/2024 | $0.00 | 06/26/2024 | Serious |
Text For Citation: 01 Item/Group: 005B Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: (a) Carlisle Packaging Company, Inc. dba Carlisle Container Company, 750 Claremont Road, Carlisle, Pennsylvania - The employer did not conduct an annual periodic inspection of lockout/tagout procedures, exposing employees to caught-in and struck-by hazards on or about March 12, 2024. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.