Violation Detail
Standard Cited: 19100134 C01 Respiratory Protection.
Inspection Nr: 1674295.015
Citation: 01005B
Citation Type: Serious
Abatement Status:
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 09/28/2023
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 12/15/2023
Gravity: 10
Report ID: 0214200
Contest Date:
Final Order: 10/24/2023
Related Event Code (REC): C
Emphasis:
Substance: 1591
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/24/2023 | $0.00 | 12/15/2023 | Serious | |
Penalty | Z: Issued | 09/28/2023 | $0.00 | 10/23/2023 | Serious |
Text For Citation: 01 Item/Group: 005B Hazard:
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: Long Shot Pistol & Rifle, LLC, 375 County Ave Secaucus, NJ a) The employer did not establish and implement a respiratory protection program for employee(s) required to wear respirators such a full-face 3M respirator with cartridges while performing cleaning activities of lead containing material. An employee performing cleaning activities was exposed to respirable lead concentrations exceeding the Permissible Exposure Limit (PEL) of 50 ug/m3 by 2.67x. The exposure is equivalent to a time-weighted average of 133.7 ug/m3 exceeded the PEL of 50 ug/m3. The sample time was 229 minutes. Zero exposure was assumed for the unsampled time period of 251 minutes. Violation occurred on or about June 10th, 2023.