Violation Detail
Standard Cited: 19100147 D05 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1616081.015
Citation: 01005B
Citation Type: Serious
Abatement Date: 03/09/2023 7
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 02/17/2023
Nr Instances: 1
Nr Exposed: 4
Related Event Code (REC): A
Gravity: 10
Report ID: 0626000
Contest Date:
Final Order: 04/14/2023
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/14/2023 | $0.00 | 03/09/2023 | Serious | |
Penalty | Z: Issued | 02/17/2023 | $0.00 | 03/09/2023 | Serious |
Text For Citation: 01 Item/Group: 005B Hazard:
29 CFR 1910.147(d)(5)(i): All potentially hazardous stored or residual energy was not relieved, disconnected, restrained or otherwise rendered safe after the application of lockout or tagout devices to energy isolating devices: On or about August 17, 2022, and at time prior thereto, all potentially hazardous energies of the of the Liberty Lift Pumping Unit/Pump Jack (Model: EG 640-365-168) were not restrained, exposing employees to struck-by, caught-in or -between hazards.