Violation Detail
Standard Cited: 19100184 E04 Slings.
Inspection Nr: 1576783.015
Citation: 01005B
Citation Type: Serious
Abatement Status: Not Completed - AD Discretion
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 08/01/2022
Nr Instances: 1
Nr Exposed: 16
Abatement Date: 08/09/2022
Gravity: 10
Report ID: 0627700
Contest Date:
Final Order: 09/01/2022
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 08/01/2022 | $0.00 | 08/09/2022 | Serious |
Text For Citation: 01 Item/Group: 005B Hazard:
29 CFR 1910.184(e)(4): The employer shall ensure that before use, each new, repaired, or reconditioned alloy steel chain sling, including all welded components in the sling assembly, shall be proof tested by the sling manufacturer or equivalent entity, in accordance with paragraph 5.2 of the American Society of Testing and Materials Specification A391-65, which is incorporated by reference as specified in �1910.6 (ANSI G61.1-1968): On or about February 14, 2022 and at times prior thereto, proof testing was not completed for a chain and welded assembly used to lift beef carcass during the slaughtering process, exposing employees to struck-by hazards.