Violation Detail
Standard Cited: 19100219 C04 II Mechanical power-transmission apparatus.
Inspection Nr: 1528324.015
Citation: 01005B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $11,703.00
Current Penalty: $0.00
Issuance Date: 09/23/2021
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 10/20/2021
Gravity: 5
Report ID: 0830100
Contest Date:
Final Order: 11/18/2021
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 11/18/2021 | $0.00 | 10/20/2021 | Serious | |
Penalty | Z: Issued | 09/23/2021 | $11,703.00 | 10/20/2021 | Serious |
Text For Citation: 01 Item/Group: 005B Hazard:
29 CFR 1910.219(c)(4)(ii): The unused keyway(s) of projecting shaft end(s) were not filled up or covered: a) Debagger gallon machine: On or about April 29, 2021, and at times prior, employees were exposed to caught in hazards while performing debagging operation and walking and working in and around exposed keyed shafts. b) Debagger half gallon machine: On or about April 29, 2021, and at times prior, employees were exposed to caught in hazards while performing debagging operation and walking and working in and around exposed keyed shafts.