Violation Detail
Standard Cited: 19100147 C07 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1518063.015
Citation: 01005B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 08/26/2021
Nr Instances: 1
Nr Exposed: 70
Abatement Date: 12/15/2021
Gravity: 10
Report ID: 0214500
Contest Date:
Final Order: 09/10/2021
Related Event Code (REC): A;R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 09/10/2021 | $0.00 | 12/15/2021 | Serious | |
Penalty | Z: Issued | 08/26/2021 | $0.00 | 09/15/2021 | Serious |
Text For Citation: 01 Item/Group: 005B Hazard:
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees a) Printing Area, Injection Molding Area and Extrusion Area: The employer did not provide training to ensure that employees have the knowledge and understanding of the use of a lock out tag out program and the dangers of the energy of machines, including but not limited to the Rutherford Tube Printing Machines, New Britain 200 Injection Molding Machines, Van Dorn 300 Injection Molding Machines, Battenfeld 35 Injection Molding Machines, Boy 22 Injection Molding Machines, NRM Plastic Extruder Machines and Davis Standard Plastic Extruder Machines, on or about March 4, 2021 to present.