Violation Detail
Standard Cited: 19100217 B14 II Mechanical power presses.
Inspection Nr: 1447344.015
Citation: 01005B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 05/06/2020
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 06/02/2020
Gravity: 10
Report ID: 0317500
Contest Date: 05/29/2020
Final Order: 09/18/2020
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 09/18/2020 | $0.00 | 06/02/2020 | Serious | |
Penalty | C: Contested | 06/01/2020 | $0.00 | 06/02/2020 | Serious | |
Penalty | Z: Issued | 05/06/2020 | $0.00 | 06/02/2020 | Serious |
Text For Citation: 01 Item/Group: 005B Hazard:
29 CFR 1910.217(b)(14)(ii): The brake monitor was not installed on the press such that it indicated when the performance of the braking system had deteriorated to the extent described in paragraph (b)(14)(i) of this section: Instances including, but not limited to, the following: b) Job site, 33 McGovern Road, Crescent, PA: On or about November 23, 2019, during hands in die production activities on the Warco part revolution press number 2, serial number 5346, located in building 4, the employer did not ensure that the brake monitor system was installed in such a manner that it indicated when the safety distance for the 2 hand controls used for machine guarding had deteriorated to an unsafe limit.