Violation Detail
Standard Cited: 19100219 E01 I Mechanical power-transmission apparatus.
Inspection Nr: 1379698.015
Citation: 01005B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 03/07/2019
Nr Instances: 1
Nr Exposed: 5
Abatement Date: 04/23/2019
Gravity: 5
Report ID: 0418100
Contest Date:
Final Order: 03/29/2019
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/29/2019 | $0.00 | 04/23/2019 | Serious | |
Penalty | Z: Issued | 03/07/2019 | $0.00 | 04/02/2019 | Serious |
Text For Citation: 01 Item/Group: 005B Hazard:
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt. On 2/13/19, in the production area on the back of the Take Up machine, employees were exposed to a belt and pulley that was left unguarded.