Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1361440.015
Citation: 01005B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $13,260.00
Issuance Date: 05/14/2019
Nr Instances: 1
Nr Exposed: 5
Abatement Date: 06/10/2019
Gravity: 5
Report ID: 0336000
Contest Date: 06/07/2019
Final Order: 01/29/2020
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 01/29/2020 | $13,260.00 | 06/10/2019 | Serious | |
Penalty | C: Contested | 06/11/2019 | $0.00 | 06/10/2019 | Serious | |
Penalty | Z: Issued | 05/14/2019 | $0.00 | 06/10/2019 | Serious |
Text For Citation: 01 Item/Group: 005B Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: A.) Champion Modular, Inc. - On or about 11/20/18, and at times prior thereto, employees were performing servicing and maintenance on equipment/machinery that included, but was not limited to, metal shear, foam sealer, elevator, foam sealer, and compactor. The company was not performing periodic inspections of the procedures on at least an annual basis with the maintenance manager.