Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1325707.015
Citation: 01005B
Citation Type: Serious
Abatement Status:
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 12/10/2018
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 12/24/2018
Gravity: 5
Report ID: 0111400
Contest Date: 01/04/2019
Final Order: 11/08/2019
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 11/08/2019 | $0.00 | 12/24/2018 | Serious | |
Penalty | C: Contested | 02/11/2019 | $0.00 | 12/24/2018 | Serious | |
Penalty | Z: Issued | 12/10/2018 | $0.00 | 12/24/2018 | Serious |
Text For Citation: 01 Item/Group: 005B Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: Location: Prosys Room, palletizer and shrink wrap machines Lock out / tag out procedures for the shrink wrap machine are inadequate. An employee was injured while performing maintenance work on the palletizer. Instance A: The procedure does not include procedures for 'troubleshooting" the machine when pneumatic power to the 'arms' must remain 'on'. Instance B: When pneumatic power can be de-energized, the procedure does not call for locking out the valve. Instance C: The procedure does not call for verifying that electric power to the machine is 'off'. Instance D: The procedures do not adequately address de-energization of the shrink wrap machine.