Violation Detail
Standard Cited: 19100023 E02 I Ladders.
Inspection Nr: 1302986.015
Citation: 01005B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 09/04/2018
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 10/28/2018
Gravity: 5
Report ID: 0418100
Contest Date:
Final Order: 09/25/2018
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 09/25/2018 | $0.00 | 10/28/2018 | Serious | |
Penalty | Z: Issued | 09/04/2018 | $0.00 | 09/28/2018 | Serious |
Text For Citation: 01 Item/Group: 005B Hazard:
29 CFR 1910.23(e)(2)(i): Steps were not uniformly spaced and arranged, with a rise of not more than 10 inches (25 cm) and a depth of not less than 7 inches (18 cm) and/or the slop of the step stringer to which the steps were attached was more than 60 degrees measured form the horizontal: On or about March 15, 2018, employees were exposed to fall hazards when employees used the job-made mobile ladder stand on line 4: a. the rise to the first step was more than 10 inches (approximately 11 1/4 inches) b. steps were not uniformly spaced and arranged (rise to first step of approximately 11 1/4 inches, rise to next step of approximately 10 inches) In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).