Violation Detail
Standard Cited: 19260800 K01 II Underground Construction
Inspection Nr: 1222253.015
Citation: 01005B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 10/31/2017
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 11/28/2017
Gravity: 10
Report ID: 0830100
Contest Date:
Final Order: 11/08/2017
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 11/08/2017 | $0.00 | 11/28/2017 | Serious | |
Penalty | Z: Issued | 10/31/2017 | $0.00 | 11/28/2017 | Serious |
Text For Citation: 01 Item/Group: 005B Hazard:
29 CFR 1926.800(k)(1)(ii): Mechanical ventilation was not provided in all underground construction work: a) Culvert Install Site: On or about May 05, 2017 and at times prior, as the controlling employer, Knife River did not ensure that its sub-contractor, Coleman Construction Inc., protected their employees in that employees were exposed to acute illness, burns, impairment of ability to self-rescue, and incapacitation while removing soil, inspecting, flame cutting, tacking and welding inside of a 36 inch culvert. The controlling employer failed to ensure that Coleman Construction Inc., provided mechanical ventilation to prevent dangerous or harmful accumulations of dusts, fumes, mists, vapors, or gases.