Violation Detail
Standard Cited: 19100212 A03 II General requirements for all machines.
Inspection Nr: 1212413.015
Citation: 01005B
Citation Type: Serious
Abatement Date: 09/12/2017 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 08/18/2017
Nr Instances: 18
Nr Exposed: 10
Related Event Code (REC):
Gravity: 5
Report ID: 0419400
Contest Date:
Final Order: 09/08/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 09/08/2017 | $0.00 | 09/12/2017 | Serious | |
Penalty | Z: Issued | 08/18/2017 | $0.00 | 09/12/2017 | Serious |
Text For Citation: 01 Item/Group: 005B Hazard:
29 CFR 1910.212(a)(3)(ii): Point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle: (a) Fabrication - On or about March 2, 2017 frame punch press guard had 4.5" by 14" opening on front side and was open on top. (b) Department 114 - On or about March 2, 2017 shop made vent jamb presses guards did not prevent operator from reaching point of operation. (c) Prime Window Department - On or about March 2, 2017 shop made slider presses guards did not prevent operator from reaching point of operation. (d) Plant site - On or about March 2, 2017 some foot pedal guards were not positioned to prevent accidental activation of the pedal and some were design with a half moon opening cut on the top front of guard exposing the pedal to accidental contact. (e) 1600 Fabrication - On or about March 2, 2017 point of operation on z-bar machine was not guarded.