Violation Detail
Standard Cited: 19100217 C03 III F Mechanical power presses.
Inspection Nr: 1148175.015
Citation: 01005B
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 07/27/2016
Nr Instances: 3
Nr Exposed: 3
Abatement Date:
Gravity: 5
Report ID: 0112000
Contest Date:
Final Order: 08/16/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/16/2016 | $0.00 | Serious | ||
Penalty | Z: Issued | 07/27/2016 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 005B Hazard:
29 CFR 1910.217(c)(3)(iii)(f): Mechanical power press(es) using presence sensing point of operation devices were not provided with guards to protect all areas of entry to the point of operation not protected by the presence sensing device(s): Press Room: On, or about, May 16, 2016, the following partial revolution mechanical power presses were not provided with barrier guards where presence sensing devices (i.e., light curtains) were not positioned to protect the point of operation or other hazardous areas of the press: A. Press 1843, Bliss. B. Press 1841, Bliss. C. Press B2660, Federal