Violation Detail
Standard Cited: 19260452 I04 Additional requirements applicable to specific types of scaffolds.
Inspection Nr: 1087369.015
Citation: 01005B
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $7,000.00
Current Penalty: $0.00
Issuance Date: 02/25/2016
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 03/01/2016
Gravity:
Report ID: 0215000
Contest Date: 03/16/2016
Final Order: 09/30/2016
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 09/30/2016 | $0.00 | 03/01/2016 | Other | |
| Penalty | C: Contested | 03/21/2016 | $7,000.00 | 03/01/2016 | Serious | |
| Penalty | Z: Issued | 02/25/2016 | $7,000.00 | 03/01/2016 | Serious |
Text For Citation: 01 Item/Group: 005B Hazard:
29 CFR 1926.452(i)(4): Outrigger beams were not secured in place against movement, and were not securely braced at the fulcrum point against tipping. On or about August 25, 2015 a) 2nd floor Southwest elevator shaft: The elevator shaft scaffold was erected using 2 Aluminum outrigger I-beams with wood planks and plywood. One outrigger beam was not secured using a shoring post. An employee fell from the platform when the platform partially collapsed.
Translate