Violation Detail
Standard Cited: 19100147 D05 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1064409.015
Citation: 01005B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 07/24/2015
Nr Instances: 3
Nr Exposed: 2
Abatement Date: 09/10/2015
Gravity: 5
Report ID: 0729300
Contest Date:
Final Order: 08/21/2015
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/21/2015 | $0.00 | 09/10/2015 | Serious | |
Penalty | Z: Issued | 07/24/2015 | $0.00 | 09/10/2015 | Serious |
Text For Citation: 01 Item/Group: 005B Hazard:
29 CFR 1910.147(d)(5)(i): Following the application of lockout or tagout devices to energy isolating devices, all potentially hazardous stored or residual energy was not relieved, disconnected, restrained, and otherwise rendered safe: Inside of the Fabrication Shop, the residual energy belonging to the following machines were not isolated by employee(s) prior to changing out the dies: a/ K.R. Wilson Hydraulic Press, m/n 3700V2-B, s/n 2051. b/ Bliss Mechanical Punch Press, m/n 5012, unknown s/n. Inside of the Machine Shop, the residual energy belonging to the following machine was not isolated by employee(s) prior to changing out the bits. a/ HAAS Vertical Machining Center, m/n BF2, m/n 2080.