Violation Detail
Standard Cited: 19100219 C04 I Mechanical power-transmission apparatus.
Inspection Nr: 1024668.015
Citation: 01005B
Citation Type: Serious
Abatement Date: 05/12/2015 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 03/26/2015
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 5
Report ID: 0111700
Contest Date:
Final Order: 04/13/2015
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/13/2015 | $0.00 | 05/12/2015 | Serious | |
Penalty | Z: Issued | 03/26/2015 | $0.00 | 05/12/2015 | Serious |
Text For Citation: 01 Item/Group: 005B Hazard:
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft: a. Location: Deburring Department - The projecting shaft ends on the Baldor buffing machine were not guarded.