Violation Detail
Standard Cited: 19260452 I01 Additional requirements applicable to specific types of scaffolds.
Inspection Nr: 1087369.015
Citation: 01005AA
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $7,000.00
Current Penalty: $6,000.00
Issuance Date: 02/25/2016
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 03/01/2016
Gravity:
Report ID: 0215000
Contest Date: 03/16/2016
Final Order: 09/30/2016
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 09/30/2016 | $6,000.00 | 03/01/2016 | Other | |
| Penalty | C: Contested | 03/21/2016 | $7,000.00 | 03/01/2016 | Serious | |
| Penalty | Z: Issued | 02/25/2016 | $7,000.00 | 03/01/2016 | Serious |
Text For Citation: 01 Item/Group: 005AA Hazard:
29 CFR 1926.452(i)(1): The employer did not ensure that the inboard end of outrigger beams, measured from the fulcrum point to the extreme point of anchorage, were not less than one and one-half times the outboard end in length. On or about August 25, 2015 a) 2nd floor Southwest elevator shaft: The elevator shaft scaffold was erected using two Aluminum outrigger I-beams with wood planks and plywood. The outrigger beams did not meet the standard's requirements. b) Southwest 7: The 2 freight elevator shaft scaffolds were erected using three Aluminum outrigger I-beams with wood planks and plywood. The outrigger beams did not meet the standard's requirements.